Cabling and Connectors
The only cables supplied with the unit are the AC line cord and the cables for the electronic
compass and the GPS receiver. All other cables must be supplied by the customer.
The following table describes the connectors on the back of the RC3000.
Designation Type Function
J1 DB15 female az/el/pol position sense
J2 DB15 female AGC port (RC3000TRK)
J3 DB15 female limit switches
J4 DB15 male Pulse sensor input (RC3000TRK)
J5 DB9 female Serial Comm. Port (RC3000CRC
J6 IEC fused Power Entry
J7 Amphenol 22-20S az/el/pol motors
J8 Amphenol 126-221 HPA disable and acc.
J9-GPS DB9 female on dongle GPS & cable, (RC3000GPS)
J9-FG DB9 female on dongle FG Compass & cable (RC3000FG)
J10 DB25 female Handheld Remote Control (RC3000HRC)
J11 F female Block LNB signal for auto peak
Attachments
The following drawings and data sheets are referenced in this document:
a) RC3000 External Interconnects Diagram
b) Lucas Accustar Electronic Clinometer
c) RC3000 Flux Gate Mounting Diagram
d) RC3000 GPS Mounting Diagram